A single-door mechanism that provides complete entry and exit control via connected Access Readers.


- (2) Lock terminals (12V and Dry)-(2) AUX terminals for an external siren and automatic door opener-(4) Additional inputs (sensors and buttons)-Connect and power using PoE++-Connect to two UniFi Access readers and two UniFi Protect cameras or UniFi Protect Chime











































































































Mechanical
Dimensions174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3')
Weight363g (12.8oz)
Enclosure materialPolycarbonate
Mounting materialPolycarbonate
Hardware
Network interface(5) 10/100/1000 Base-T
Power methodPoE++ UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
Max. power consumptionWithout PoE output: 30W With PoE output: 50W
PoE input50V DC, 1A
PoE outputPoE passthrough, (4) PoE, 50V DC, total 20W
LEDsWhite/blue(Learn more)
Button(1) Factory reset
Digital inputRequest to exit/request to enter/remote release/door position sensor
Dry output relayLock: 30V DC, 1A Aux: 30V DC, 1A
Powered output relayLock: 12V DC, 1A Aux: 12V DC, 0.33A 12V DC, 0.33A
Recommended max. cable length








































18 AWG UACC-Cable-DoorLockRelay length20 AWG length22 AWG length24 AWG length
UA-Lock-Electric (400mA)100 m (328 ft)66 m (217 ft)42 m (138 ft)25 m (82 ft)
UA-Lock-Magnetic-270kg (800mA)46 m (151 ft)30 m (98 ft)20 m (66 ft)12 m (29 ft)
UA-Lock-Magnetic-540kg (500mA)80 m (262 ft)51 m (167 ft)32 m (105 ft)20 m (66 ft)
Other locks (1A)36 m (118 ft)24 m (79 ft)15 m (49 ft)9 m (30 ft)

PoE cabling requirementsCable 5e cabling is the minimum performance category recommended. The performance category used should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm2) for patch cords; 24 AWG (0.21 mm2) for horizontal or riser cable.
Operating environmentIndoor use only
Ambient operating temperature0 to 40°C (32 to 104°F)
Ambient operating humidity5 to 95% non-condensing
UL 294 levelDestructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
UL 294 statementCompliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 GradeGrade assignment: 1
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelUA-Hub-Door002, V01