The Wi-Fi gas leak detector, designed to detect natural and coal gas leaks, emits a 75 dB audible signal and sends notifications to a mobile app. It connects directly to a 2.4 GHz Wi-Fi network, has 12 V solenoid valve and NC/NO relay outputs.
The Wi-Fi gas leak detector, designed to detect natural and coal gas leaks, emits a 75 dB audible signal and sends notifications to a mobile app. It connects directly to a 2.4 GHz Wi-Fi network, has 12 V solenoid valve and NC/NO relay outputs.




The Wi-Fi gas leak detector, designed to detect natural and coal gas leaks, emits a 75 dB audible signal and sends notifications to a mobile app. It connects directly to a 2.4 GHz Wi-Fi network, has 12 V solenoid valve and NC/NO relay outputs.
Guarantee
24 month
Delivery from Europe in
15 - 16
business days
Wi-Fi gas detector for detecting natural and coal gas leaks. The device features a 75 dB alarm and notifications in the mobile app. The detector connects directly to a 2.4 GHz Wi-Fi network and is equipped with 12 V solenoid valve and NC/NO relay outputs.
Product information | |
|---|---|
| Product type | Wi-Fi Natural and Coal Gas Leak Detector |
| Brand | Moes |
| Model | WSS-S-GL |
| Sensor type | Semiconductor gas sensor |
Technical specifications | |
| Power source | AC 100-240V |
| Average energy consumption | <2W |
| Natural gas danger threshold | 6% LEL ±3% LEL |
| Wi-Fi standard | 2.4 GHz, IEEE 802.11 a/b/g/n |
| Operating temperature | −10°C-+50°C |
| Operating humidity | 10%-95% RH |
Outputs and installation | |
| Solenoid valve output | 12V/100kPa |
| Relay output | NC/NO relay, normally closed by default |
| Recommended installation location | Install near a gas appliance. If the gas is lighter than air, install the device 0.3-1 m below the ceiling; if the gas is heavier than air, install 0.3-1 m above the floor. |
| Detection zone | Up to 3 m diameter |
Safety warning | |
| Warning | Use only for detecting natural and coal gas leaks. This detector is not a substitute for proper maintenance of gas appliances and emergency response. Install as recommended, do not block ventilation openings and inspect the unit regularly. If the alarm sounds, keep away from flames, sparks and electrical switches, leave the room and contact the appropriate emergency services or the gas supply company. |
| Height | 100mm |
| Length | 250mm |
| Weight | 300g |
| Width | 200mm |