Shelly Analog Expansion Module - Shelly Analog 0-30 V Accessory for "The Pill" Module
Product reference: 14-3800238073596

" Shelly Analog 0-30V Add-On" extends the functionality of "The Pill", providing the ability to measure 0-30 V DC voltage and connect 0-5 V analog sensors. The module has configurable 3.3 V IO2 and IO3 contacts, 5 V and GND terminals; its dimensions are 36.5 × 26.5 × 11.5 mm.

Shelly Analog Expansion Module - Shelly Analog 0-30 V Accessory for "The Pill" Module

Product reference: 14-3800238073596

" Shelly Analog 0-30V Add-On" extends the functionality of "The Pill", providing the ability to measure 0-30 V DC voltage and connect 0-5 V analog sensors. The module has configurable 3.3 V IO2 and IO3 contacts, 5 V and GND terminals; its dimensions are 36.5 × 26.5 × 11.5 mm.

You have 3 products in compare list, please remove someone and try again
  • Add to favorites products
  • Added to favorites products
  • Removed to favorites product
Add to compare
23,19 €
Product in warehouse

Guarantee
24 month

Delivery from Europe in
15 - 16
business days

Your message has been successfully sent!
Fill in the required fields*
Not available

" Shelly Analog 0-30V" add-on module for "The Pill"


The " Shelly Analog 0-30V" add-on module expands the capabilities of "The Pill" - it allows you to measure 0-30 V DC voltage and connect 0-5 V analog sensors. The module has configurable 3.3 V IO2 and IO3 contacts, 5 V and GND terminals. Dimensions - 36.5 × 26.5 × 11.5 mm.


  • Extends " Shelly The Pill" and provides the ability to measure 0-30 V DC voltage
  • Suitable for monitoring batteries, power supplies and 0-5 V analog sensors
  • Configurable 3.3V IO2 and IO3 pins can function as digital inputs or outputs
  • Compact black add-on module with dimensions of 36.5 × 26.5 × 11.5 mm and weight of 8 g

Product information

Product type Analog " Shelly The Pill" expansion module
Brand " Shelly "
Model Analog 0-30V Add-On
Compatibility " Shelly The Pill"
Connection required " Shelly 5-Terminal Add-on"

Technical data

Voltage measurement accuracy ±(2% + 5 digits)
Analog sensor compatibility 0-5 V analog sensors
Configurable contacts IO2 and IO3, 3.3 V logic level
Digital input trigger voltage LOW: < 0.83V; HIGH: > 2.48V
Maximum digital input voltage 3.3V
Maximum switching voltage 3.3V
Maximum switching current 20 mA
Available terminals 5V and GND

Physical properties

Dimensions 36.5 × 26.5 × 11.5mm
Weight 8 grams
Color Black

Terms of Use

Operating temperature from 0°C to 40°C
Storage temperature from −20 °C to 40 °C
Humidity 30-70% relative humidity
Maximum working height 2,000 m above sea level

Safety warning

Warning Use only with " Shelly The Pill" and the required "5-Terminal Add-on". Connect only low voltage DC sources and sensors that meet the specified limits. Do not exceed 30 V DC on the analog measurement input or 3.3 V on the digital IO pins. Disconnect power before mounting or connecting wires.

Height50mm
Length150mm
Weight15 grams
Width100mm
Offensive and promotional comments are unpublished.
Testimonials not found!
Testimonial