Jeweler communication technologyProprietary wireless technology for transmission of alarms and events., Features:, Two-way communication., Protection against device spoofing., Block encryption featuring a floating key., Instant notifications., Remote configuration via the Ajax apps., Learn more
Radio frequency bands866.0 - 866.5 MHz 868.0 - 868.6 MHz 868.7 - 869.2 MHz 905.0 - 926.5 MHz 915.85 - 926.5 MHz 921.0 - 922.0 MHz, Depends on the region of sale.
Maximum effective radiated power (ERP)up to 20 mW, Automatic power control to reduce power consumption and radio interference.
Radio signal modulationGFSK
Radio communication rangeup to 5,500 ft, Between the detector and a hub (or radio signal range extender) in an open space., Calculate radio communication range at the facility
Radio encryptionAll the data stored and transmitted are protected by block encryption with a floating key.
Radio frequency jumpsTo prevent radio interference and jamming., Learn more
Smoke detection
Sensitive elementdouble-spectrum optical sensor, Recognizes smoke by the size of particles in the air.
Protection against false alarmsDoes not react to water vapor.
Patented smoke chamberProtects the smoke sensor from dust, dirt, and insects.
Dangerous temperature detection
Sensitive elementaccording to the requirements for Class A1R heat detectors, Requirements of EN 54-5 and BS 5446-2 standards.
High temperature alarmat temperatures above 147°F
Sudden temperature jump signalwhen the temperature rises more than 50°F in 1 minute or less
Carbon monoxide (CO) detection
Sensitive elementchemical CO sensor
Alarm if the accumulated CO dose is exceededmore than 50 ppm (0.005%) — no more than in 90 minutes more than 100 ppm (0.01%) — no more than in 40 minutes more than 300 ppm (0.03%) — no more than in 3 minutes, CO concentration of 400 ppm (0.04%) within 3 hours can be life-threatening. The detector stops notifying about the dangerous level of carbon monoxide when the concentration drops to 50 ppm (0.005%) within one minute.
Sensor life span10 years, After 10 years of operation, the detector must be replaced with a new one.
Additional features
Integrated sirenvolume 85 dB at a distance of 9 ft, Sound notification of alarms. Active until the reason for triggering is eliminated or until the user disables notification.
Signals from interconnected fire detectorsvia primary interconnection, If one of the fire detectors in the system detects a threat, it sends an alarm to the hub. Within 20 seconds, the hub initiates an interconnected alarm and sends data to Ajax apps.
LED indicationgreen is a power indication, A LED indicator on the device enclosure lights up once every 56 seconds. The indication meets the requirements of EN 50291., yellow is an indication of malfunctions, A LED indicator on the device enclosure lights up when malfunctions are detected. For example, in the case of discharged batteries, contamination of the smoke chamber, or end of the service life., red is an indication of fire alarms, A LED indicator on the device enclosure lights up when the detector registers a fire alarm.
Button on the front of the detectorIn normal mode, when pressed, it starts the smoke chamber test. In the event of an alarm or malfunction, the pressing turns off the detector sound notification.
Protection against sabotage
Tamper signalAlerts of attempts to detach the detector from the surface or remove the mounting panel., Learn more
Protection against counterfeitingdevice authentication
Communication failure detectionwithin 15 minutes, The time to detect communication loss depends on the settings for the number of undelivered data packages (specified in the Jeweler or Jeweler/Fibra settings). The polling interval is fixed at 300 seconds., Learn more
Power supply
For FireProtect 2 RB (heat/smoke/CO)2 × CR123A battery, Up to 7 years of battery life.
Housing
Dimensions4.88″ × 4.88″ × 1.77″
Weight9.68 oz
Operating temperature limitfrom 32°F to 122°F
Humidityup to 80%
Protection classIP20
Manufacturer
Ajax
Manufacturer code
AJFIREPROTECT
Weight
0.272 kg