Residual current relay with circuit breaker Hager AD960J (2P, 10A, type A, 30mA, 230V)
Product reference: 26-3250611040774
  • Type: Residual current circuit breaker (RCBO)
  • Model: Hager AD960J
  • Number of poles: 2P
  • Rated current: 10 A
  • Type: A (for alternating and pulsating direct current)
  • Leakage current: 30 mA
  • Voltage: 230V
  • Manufacturer: Hager

Residual current relay with circuit breaker Hager AD960J (2P, 10A, type A, 30mA, 230V)

Product reference: 26-3250611040774
  • Type: Residual current circuit breaker (RCBO)
  • Model: Hager AD960J
  • Number of poles: 2P
  • Rated current: 10 A
  • Type: A (for alternating and pulsating direct current)
  • Leakage current: 30 mA
  • Voltage: 230V
  • Manufacturer: Hager
You have 3 products in compare list, please remove someone and try again
  • Add to favorites products
  • Added to favorites products
  • Removed to favorites product
Add to compare
56,58
Product in warehouse

Guarantee
24 month

Delivery from Lithuania in
2 - 4
business days

Your message has been successfully sent!
Fill in the required fields*
  • General information
  • Product name Hager AD960J
  • Type RCBO (Residual Current Circuit Breaker with Overcurrent Protection)
  • Pole configuration 1P+N
  • Shutdown curve C
  • Rated current 10 A
  • Rated residual operating current Idn 30 mA
  • Residual current type A
  • Rated short-circuit breaking capacity Icn (230 V AC, IEC 60898-1) 6kA
  • Rated insulation voltage Ui 500V
  • Rated impulse withstand voltage Uimp 4,000V
  • Rated operating voltage Ue 240 V AC
  • Maximum operating voltage 240V
  • Overvoltage category (IEC 60947-1) 3
  • Correction factor of rating current (2 devices side by side) 1
  • Correction factor (3 devices side by side) 0.95
  • Correction factor (4-5 devices side by side) 0.90
  • Correction factor (6 devices side by side) 0.85
  • Thermal operation threshold (AC) 1.13 - 1.45 A
  • IP protection class IP2X
  • Frequency 50Hz
  • Max height 2,000 m
  • Class of energy limitation I²t 3
  • Operating temperature -25 to +40 °C
  • Storage/transport temperature -25 to +70 °C
  • Electrical endurance 2,000 cycles
  • Mechanical durability 2,000 operations
  • Total power loss at In 3.40W
  • Connection type Screw terminal (top), Biconnect (bottom)
  • Nominal tightening torque 2.10 Nm
  • Conductor cross-section (flexible) 1-16 mm²
  • Conductor cross-section (rigid) 1-25 mm²
  • Number of modules 2
  • Height 83 mm
  • Width 35mm
  • Depth 68 mm

ManufacturerHager
Manufacturer codeHAD960J
Weight0.000000 kg
Offensive and promotional comments are unpublished.
Testimonials not found!
Testimonial