Control panel S16 cmR+Voucher SECOLINK (5 / 10 zones, max 16 zones 3PGM, 4 areas)
Product reference: 26-CASS16CMRVOUCHER
  • 5/10 zones
  • Maximum 16 zones
  • 3PGM
  • 4 areas
  • 16 timers

Control panel S16 cmR+Voucher SECOLINK (5 / 10 zones, max 16 zones 3PGM, 4 areas)

Product reference: 26-CASS16CMRVOUCHER
  • 5/10 zones
  • Maximum 16 zones
  • 3PGM
  • 4 areas
  • 16 timers
You have 3 products in compare list, please remove someone and try again
  • Add to favorites products
  • Added to favorites products
  • Removed to favorites product
Add to compare
109,26
Product in warehouse

Guarantee
24 month

Delivery from Lithuania in
2 - 4
business days

Your message has been successfully sent!
Fill in the required fields*
  • Home
  • Maximum number of zones in the system 16
  • Number of PGM outputs on the board 3
  • Maximum number of PGM outputs in the system 16
  • Number of users + installer codes 31+1
  • Attack code There is
  • User and installer code recovery There is
  • Key/push-button switch zone (key-switch) There is
  • Areas 4
  • Common corridor area There is
  • Number of timers in the system 16
  • Maximum number of control panels/modules in the system 3
  • Compatibility with control panels All SECOLINK control panels
  • Event log volume In the control panel - 256, in the set with the control panel - 512
  • Interface with transmitters and communicators from other manufacturers None
  • Data bus protocol CRBUS
  • Roller blinds lifting sensor zone There is
  • Vibration detection sensor area There is
  • Vibration detection zone sensitivity (speed) 0.01 - 0.25 sec.
  • Sensor zone sensitivity (speed) 0.1 - 2.5 seconds
  • Nominal power supply voltage of the control panel (AC) ~18 - 20V
  • Minimum power supply voltage of the control panel (AC) ~16V
  • Maximum power supply voltage of the control panel (AC) ~22
  • Maximum continuous control panel output current (I+AUX + I+BELL + IBATTERY CHARGING) ≤0.7A
  • Maximum current of the AC primary circuit slow-blow fuse 250 mA
  • Maximum current consumed from the AC mains 150mA
  • Minimum voltage of +AUX, +BELL outputs 12V
  • Maximum +AUX, +BELL output voltage 13.9V
  • Maximum +AUX drain current +0.5A
  • Maximum short-term leakage current +BELL (with battery) +2 A
  • Maximum inflowing current -PGM1 -0.15A
  • Maximum incoming current -PGM2 -0.15A
  • +BELL, +AUX short circuit, overload protection Electronic
  • Battery charging, +BELL, +AUX current measurement There is
  • Disconnecting a faulty battery There is
  • Maximum battery charging current +0.2A
  • Maximum current of the battery circuit fast-acting fuse 3.15A
  • The control panel disconnects the battery when the battery voltage is lower than 9.5V
  • Product compliance with standards EN50131, Grade2
  • Backup power supply recommended 12 V, 2.2 - 7Ah
  • Overall dimensions W x H mm 145 x 77
  • Product compliance with environmental standards ROHS
  • Operating temperature From -10oC to +50oC
  • Remote programming of control panel settings There is

ManufacturerSecolink
Manufacturer codeCASS16CMRVOUCHER
Weight0 kg
Offensive and promotional comments are unpublished.
Testimonials not found!
Testimonial