Automatic transfer switch HiSmart W2R-3P 220V 100A
Features:Automatic transfer switch 220VAC, 100A for emergency power supply system 50/60Hz, transfer time <50ms.The switch can also be operated manually.The switch complies requirements of low voltage switch gear and control gear specified by IEC 60947-6-1, IEC 60947-3.Compact design, reliable switching, easy installation on a DIN rail.It is widely applicable in various occasions where continuous power failure is not allowed.
Specifications:Voltage: AC220V.Current: 100A.Frequency: 50/60Hz.Number of contacts: 3.Insulation voltage (Ui): AC 690V.Rated voltage (Ue): AC 400V.Rated conditional short-circuit current: 50 kA.SCPD (fuse): RT16-00-63A.Rated impulse withstand voltage: 8 kV.Main voltage: AC 220V.Auxiliary circuit: AC 220V.Contact transfer time: <50 ms.Operating transfer time: <50ms.Return transfer time: <50ms.Off- time: <50ms.Installation: on a DIN rail.Dimensions: 125x95x80 mm.Mechanical life: 5000 times.Electrical life: 2000 times.Operating temperature: -5°C ~ +40°C (24-hour average temperature should not be more than 35°C).Weight: 633g.
Warranty: 24 months.
Download Manual
Features:Automatic transfer switch 220VAC, 100A for emergency power supply system 50/60Hz, transfer time <50ms.The switch can also be operated manually.The switch complies requirements of low voltage switch gear and control gear specified by IEC 60947-6-1, IEC 60947-3.Compact design, reliable switching, easy installation on a DIN rail.It is widely applicable in various occasions where continuous power failure is not allowed.
Specifications:Voltage: AC220V.Current: 100A.Frequency: 50/60Hz.Number of contacts: 3.Insulation voltage (Ui): AC 690V.Rated voltage (Ue): AC 400V.Rated conditional short-circuit current: 50 kA.SCPD (fuse): RT16-00-63A.Rated impulse withstand voltage: 8 kV.Main voltage: AC 220V.Auxiliary circuit: AC 220V.Contact transfer time: <50 ms.Operating transfer time: <50ms.Return transfer time: <50ms.Off- time: <50ms.Installation: on a DIN rail.Dimensions: 125x95x80 mm.Mechanical life: 5000 times.Electrical life: 2000 times.Operating temperature: -5°C ~ +40°C (24-hour average temperature should not be more than 35°C).Weight: 633g.
Warranty: 24 months.
Download Manual
Offensive and promotional comments are unpublished.
Testimonials not found!
Request for product delivery/order