Heating Manifold - 3 Loops NC AC230V Thermal Actuators with Flow Meters
Product reference: 14-9990000260386

Heating manifold with three loops, NC AC230V thermal actuators and flow meters, for underfloor heating. A metal mounting box is included, the dimensions of which are 640x530x118mm, and the power consumption of the actuators is 2W.

Heating Manifold - 3 Loops NC AC230V Thermal Actuators with Flow Meters

Product reference: 14-9990000260386

Heating manifold with three loops, NC AC230V thermal actuators and flow meters, for underfloor heating. A metal mounting box is included, the dimensions of which are 640x530x118mm, and the power consumption of the actuators is 2W.

You have 3 products in compare list, please remove someone and try again
  • Add to favorites products
  • Added to favorites products
  • Removed to favorites product
Add to compare
19866
Product in warehouse

Guarantee
0 month

Delivery from Europe in
4 - 5
business days

Your message has been successfully sent!
Fill in the required fields*

Heating Manifold with 3 Loops and Thermodynamic Actuators NC AC230V and Flow Meters


Heating manifold with 3 loops, NC AC230V thermodynamic actuators and flow meters for underfloor heating. The kit includes a metal mounting box, the size of which is 640x530x118mm, and the thermodynamic actuators consume 2W of energy.


  • Individually controls heating zones for efficient temperature control.
  • NC thermodynamic actuators are included for precise heat distribution and energy savings.
  • Easy installation with VA80 threaded adapter for reliable connections.
  • Mounted collector cabinet with 135-degree opening doors for convenient access.

Features

Product Type Heating Manifold
Model Heating Manifold with 3 Loops

Specifications

Mounting Type Wall mounted
Dimensions 640 x 530 x 118 mm (W x H x D)
Depth 110mm
Door Dimensions 578mm x 475mm
Number of Flow Meters 3 pcs
Thermodynamic Actuators 3 pcs
Air Outlets 2 pcs
Heating Cycle Pipe Adapters 3 pcs (16mm)
Color Light Gray

Thermodynamic Actuator Specifications

Purpose Water heating system
Operation Type NC (Normally Closed)
Operating Voltage AC 230V, 50/60Hz
Starting Current Max. 300 mA
Power Consumption 2W
Installation Connected to the manifold via an adapter
Adapter VA 80
Cable Length 90 cm
Operating Temperature 0°C to +60°C
Storage Temperature -25°C to +65°C
Operating Humidity < 80% RH (non-condensing)
Security Class IP54
Dimensions Ø49.4mm x 56.6mm