Circuit breaker Hager NDN116 (1P, 16A, D, 10kA, 400V)
Product reference: 26-HNDN116
  • Type: Automatic switch
  • Model: Hager NDN116
  • Number of poles: 1P
  • Rated current: 16 A
  • Characteristic: D
  • Short-time short-circuit current: 10 kA
  • Voltage: 400V
  • Manufacturer: Hager

Circuit breaker Hager NDN116 (1P, 16A, D, 10kA, 400V)

Product reference: 26-HNDN116
  • Type: Automatic switch
  • Model: Hager NDN116
  • Number of poles: 1P
  • Rated current: 16 A
  • Characteristic: D
  • Short-time short-circuit current: 10 kA
  • Voltage: 400V
  • Manufacturer: Hager
You have 3 products in compare list, please remove someone and try again
  • Add to favorites products
  • Added to favorites products
  • Removed to favorites product
Add to compare
1676
Product in warehouse

Guarantee
24 month

Delivery from Lithuania in
2 - 6
business days

Your message has been successfully sent!
Fill in the required fields*
Not available
  • General information
  • Rated current 16 A
  • Rated operational short-circuit breaking capacity Ics (230 V AC, IEC 60947-2) 7.50kA
  • Rated short-circuit breaking capacity Icn (230 V AC, IEC 60898-1) 10kA
  • Rated ultimate short-circuit breaking capacity Icu (230 V AC, IEC 60947-2) 15kA
  • Rated current at -25 °C 20.49 A
  • Rated current at -20 °C 20.12 A
  • Rated current at -15 °C 19.75 A
  • Rated current at -10 °C 19.37 A
  • Rated current at -5 °C 18.98 A
  • Rated current at 0 °C 18.58 A
  • Rated current at 5 °C 18.18 A
  • Rated current at 10 °C 17.76 A
  • Rated current at 15 °C 17.34 A
  • Rated current at 20 °C 16.90 A
  • Rated current at 25 °C 16.46 A
  • Rated current at 30 °C 16.00 A
  • Rated current at 35 °C 15.53 A
  • Rated current at 40 °C 15.04 A
  • Rated current at 45 °C 14.54 A
  • Rated current at 50 °C 14.02 A
  • Rated current at 55 °C 13.48 A
  • Rated current at 60 °C 12.91 A
  • Rated current at 65 °C 12.32 A
  • Rated current at 70 °C 11.70 A
  • Pole type 1P
  • Shutdown curve D
  • Number of modules 1
  • Rated short-circuit breaking capacity Icn (IEC 60898-1) 10kA
  • Nominal tightening torque (upper terminal) 2.80 Nm
  • Nominal tightening torque (lower terminal) 2.80 Nm
  • Nominal tightening torque (total) 2.80 Nm
  • Bottom connection type (modular units) Biconnect
  • Top connection type (modular units) Screw terminal
  • 360° mounting position Yes
  • Rated operating voltage Ue 230-400V AC
  • Rated insulation voltage Ui 500V
  • Rated impulse withstand voltage Uimp 6,000V
  • Frequency 50-60Hz
  • Input/output cross-section (rigid conductors) 1-35 mm²
  • Input/output cross-section (flexible conductors) 1-25 mm²
  • IP protection class IP20
  • Pollution degree (IEC 60664 / IEC 60947-2) 2
  • Operating temperature -25 to +70 °C
  • Total power loss at In 2.62W
  • Electrical durability (switching cycles) 4,000
  • Mechanical durability (switching cycles) 20,000
  • Connection type Screw terminal
  • Top connection arrangement (modular units) Aligned terminals
  • Bottom connection arrangement (modular units) Aligned terminals
  • Height 83 mm
  • Width 17.5 mm
  • Depth 70 mm